Grundfos borehole motors and accessories
Official Grundfos distributor, SINES Export supplies everything that goes around an SP submersible pump: MS 402, MS 4000 and MS 6000 motors, MMS rewindable motors, MP 204 electronic protection, motor cables and submersible cables, cable joint kits, non-return valves, strainers and cooling sleeves. Everything needed to equip a new borehole, but above all to put back into service a pump whose motor, cable or joint has failed, without buying the complete set again.
A submersible motor rarely burns out without a reason: insulation fault at the joint, insufficient cooling, dry running or too-frequent starts. Each product page sets out the rules of the Grundfos data booklet, and the guide below brings together the essentials: choosing the motor, cooling it, sizing the cable and protecting it.
For a replacement, send us the pump and motor nameplates, the installation depth and the available voltage: we prepare the complete motor, cable, joint and protection set, for worldwide export. In solar pumping, the RSI inverter has its own built-in protections.
Single-phase MS 402 from 0.37 to 1.5 kW and three-phase MS 4000 up to 7.5 kW, for 4" SP pumps: replacement and repair.
From 5.5 to 30 kW at 3 × 400 V, direct-on-line or star-delta start, for medium- and high-flow SP pumps.
MMS 6, MMS 8000 and MMS 10000 from 22 to 147 kW: repairable by rewinding, for large water supply boreholes.
Insulation before start, temperature, overload and dry running; PR 5714 relay and Pt100 / Pt1000 sensors.
MS motor cables with plug, 4G1.5 submersible cables, KM heat-shrink cable joint kits and cable clips.
Non-return valves, stainless-steel suction strainers and cooling sleeve supports for SP pumps.
Which Grundfos motor or accessory should you choose?
| Range | Diameter | Power range | Power supply | Used for |
|---|---|---|---|---|
| MS 402 | 4" | 0.37 to 1.5 kW | 1 × 230 V | 4" SP pumps in single-phase, sites without a three-phase supply |
| MS 4000 | 4" | 2.2 to 7.5 kW | 3 × 400 V | 4" SP pumps in three-phase, solar pumping with RSI |
| MS 6000 | 6" | 5.5 to 30 kW | 3 × 400 V | 6" SP pumps (SP 17 to SP 95 depending on power), water supply and irrigation |
| MMS | 6", 8", 10" | 22 to 147 kW | 3 × 400 V | Large boreholes, motors repairable by rewinding |
| MP 204 | control box | 3 to 999 A | 100 to 480 V | Motor protection on mains or generator supply |
| Cables and joints | 4" and 6" | 1.5 to 10 mm² | depending on motor | Motor cable replacement, extension, watertight joint |
The motor is chosen according to the pump: diameter, power stated on the SP pump nameplate and voltage available on site. The cable is then sized according to the length between the control box and the pump, and the protection according to the rated motor current. For a replacement, a motor identical to the original avoids any modification to the riser pipe and the control box.
In solar pumping, the RSI inverter controls the MS 4000 and MS 6000 motors and has its own built-in protections (overvoltage, overload, overtemperature), with a dry-running sensor as an accessory. The MP 204 is worthwhile on installations powered by the mains or a generator.
Equipping an SP borehole: motor, cable, protection
A submersible pump almost never fails by itself: motors burn out through insulation faults, overheating or dry running, and all three causes are dealt with at installation. Here are the rules from the Grundfos data booklet that we apply to every borehole.
Choosing the motor
The motor is chosen with the pump: its power P2 must cover the duty point, and its diameter must fit the borehole. 4" MS 402 and MS 4000 up to 7.5 kW, 6" MS 6000 from 5.5 to 30 kW, rewindable MMS from 22 to 147 kW in the Grundfos catalogue. The MMS is repaired by rewinding, an asset on sites far from Grundfos workshops.
Cooling the motor
Water must flow along the motor at no less than 0.15 m/s for water up to 40 °C. Place the motor above the borehole screens; if the borehole is much wider than the pump, if the pump is below the screens or installed horizontally, add a cooling sleeve.
Sizing the cable
The voltage drop in the submersible cable must not exceed 3 %; the table below gives the maximum length between control box and pump for direct-on-line starting at 3 × 400 V. With star-delta starting, the length can be multiplied by 1.73. A larger cross-section reduces losses: on a borehole that runs all year round, it quickly pays for itself.
Protecting
An MP 204 protection unit measures the insulation before each start, monitors the temperature via the Tempcon sensor and stops the pump in the event of underload, a sign of dry running. Add a surge arrester, respect the motor's number of starts per hour and measure the insulation at every service visit: below 0.5 MΩ, action is needed.
Maximum submersible cable length, in metres from the control box to the pump
3 × 400 V, 50 Hz, direct-on-line start, voltage drop 3 %, water at 30 °C (Grundfos SP data booklet). For star-delta, multiply by 1.73.
| Motor | kW | In (A) | 1.5 mm² | 2.5 mm² | 4 mm² | 6 mm² | 10 mm² | 16 mm² | 25 mm² | 35 mm² |
|---|---|---|---|---|---|---|---|---|---|---|
| 4" | 0.37 | 1.4 | 462 | 767 | – | – | – | – | – | – |
| 4" | 0.55 | 2.2 | 294 | 488 | 777 | – | – | – | – | – |
| 4" | 0.75 | 2.3 | 250 | 416 | 662 | 987 | – | – | – | – |
| 4" | 1.1 | 3.4 | 169 | 281 | 448 | 668 | – | – | – | – |
| 4" | 1.5 | 4.2 | 132 | 219 | 348 | 520 | 857 | – | – | – |
| 4" | 2.2 | 5.5 | 92 | 153 | 244 | 364 | 602 | 951 | – | – |
| 4" | 3 | 7.85 | 69 | 114 | 182 | 271 | 447 | 705 | – | – |
| 4" | 4 | 9.6 | 54 | 90 | 143 | 214 | 353 | 557 | 853 | – |
| 4" | 5.5 | 13 | 39 | 66 | 104 | 156 | 258 | 407 | 624 | 855 |
| 4" | 7.5 | 18.8 | 28 | 47 | 75 | 112 | 185 | 291 | 445 | 609 |
| 6" | 5.5 | 13.6 | 40 | 66 | 105 | 157 | 258 | 407 | 622 | 850 |
| 6" | 7.5 | 17.6 | 29 | 49 | 78 | 117 | 193 | 304 | 465 | 637 |
| 6" | 9.2 | 21.8 | 23 | 39 | 62 | 93 | 154 | 243 | 372 | 510 |
| 6" | 11 | 24.8 | – | 34 | 53 | 80 | 132 | 209 | 320 | 440 |
| 6" | 13 | 30 | – | 28 | 45 | 68 | 112 | 176 | 270 | 370 |
| 6" | 15 | 34 | – | – | 39 | 59 | 97 | 154 | 236 | 324 |
| 6" | 18.5 | 42 | – | – | – | 48 | 80 | 126 | 193 | 265 |
| 6" | 22 | 48 | – | – | – | 41 | 67 | 107 | 164 | 225 |
| 6" | 26 | 57 | – | – | – | – | 57 | 90 | 138 | 189 |
| 6" | 30 | 66.5 | – | – | – | – | 49 | 78 | 119 | 164 |
| Max. cable current | 23 A | 30 A | 41 A | 53 A | 74 A | 99 A | 131 A | 162 A |
Frequently asked questions
Can the motor of an SP pump be replaced on its own?
Yes. If the pump end is in good condition, the motor is replaced by an MS or MMS of the same power and diameter, with a new motor cable. We check the compatibility between pump and motor with you from the nameplate.
Which cable cross-section for my borehole?
It depends on the power, the current and the length between the control box and the pump. The table above gives the maximum lengths for a 3 % voltage drop with direct-on-line starting at 3 × 400 V; send us these three figures and we will do the calculation.
Why a rewindable motor?
An MMS whose winding has burnt out can be rewound in a specialist workshop instead of being replaced. For high power ratings and remote sites, this reduces the cost and the time needed to return to service.
Is the MP 204 useful with an RSI solar inverter?
No: the MP 204 is not used downstream of a frequency converter or an inverter. The RSI has its own built-in protections (overload, underload, overvoltage). The MP 204 is used on pumps powered by the mains or a generator.