The MS 402 covers the low power ratings, from 0.37 to 2.2 kW, in single-phase 2-wire or 3-wire or in three-phase; the single-phase 2-wire MS 402 has built-in motor protection and connects directly to the mains, while the 3-wire version connects via a starter box. Its shaft seal is a rubber lip seal approved for drinking water, with a ceramic radial bearing and a ceramic-carbon thrust bearing. The MS 4000, three-phase from 0.75 to 7.5 kW, has a spring-loaded ceramic/tungsten carbide mechanical shaft seal with sand shield, or SiC/SiC in the R version; it withstands 100 starts per hour and 300 per day, and is available in a T60 industrial version for liquid up to 60 °C.
All MS motors are factory-filled with a motor liquid based on monopropylene glycol, non-toxic and frost-proof down to -20 °C. Before installation, after long storage or transport, the level is checked and topped up with demineralised water or clean tap water through the filling hole (at the bottom of the MS 402, on the end shield of the MS 4000), with the motor tilted, turning the shaft to expel the air. The insulation resistance is measured before the cable is connected, after the joint is made and once the motor is in the borehole: below 0.5 MΩ, the motor, the cable or the joint must be repaired.
Cooling depends on the water velocity along the motor: at least 0.15 m/s for liquid up to 40 °C. In a borehole much wider than the pump, or when the pump is placed below the borehole screens or horizontally, a cooling sleeve is required. The motor operates permanently submerged, with the pump inlet always under water.
Applications: replacing the motor of a failed 4" SP pump, fitting a new SP pump end to an existing motor, changing from single-phase to three-phase, repairing domestic, agricultural and village boreholes.
Official Grundfos distributor, SINES Export supplies Grundfos motors, protection units, cables and borehole accessories to installers, drillers, operators and NGOs, for worldwide export. For a replacement, send us the pump and motor nameplates: we check compatibility and prepare the complete motor, cable, joint and protection set. See also the SP submersible pumps, the RSI solar inverter and the “equipping an SP borehole” guide.
MS 402 single-phase 1 × 230 V, 50 Hz
| Power P2 |
Current In |
Efficiency at 100 % |
Cos φ at 100 % |
Ist / In |
Length |
Weight |
| 0.37 kW | 3.95 A | 57 % | 0.77 | 3.4 | 256 mm | 6.8 kg |
| 0.55 kW | 5.8 A | 59.5 % | 0.74 | 3.5 | 291 mm | 8.2 kg |
| 0.75 kW | 7.45 A | 60 % | 0.79 | 3.6 | 306 mm | 8.9 kg |
| 1.1 kW | 7.3 A | 72.5 % | 0.99 | 4.3 | 346 mm | 10.5 kg |
| 1.5 kW | 10.2 A | 71 % | 0.98 | 3.9 | 346 mm | 11 kg |
MS 4000 three-phase 3 × 400 V, 50 Hz
| Power P2 |
Current In |
Efficiency at 100 % |
Cos φ at 100 % |
Ist / In |
Length |
Weight |
| 2.2 kW | 6.05 A | 74.5 % | 0.74 | 4.5 | 456 mm | 16 kg |
| 3 kW | 7.85 A | 75.2 % | 0.77 | 4.5 | 496 mm | 17 kg |
| 4 kW | 9.6 A | 78 % | 0.8 | 4.8 | 576 mm | 21 kg |
| 5.5 kW | 13 A | 79.8 % | 0.81 | 4.9 | 676 mm | 26 kg |
| 7.5 kW | 18.8 A | 78.2 % | 0.78 | 4.5 | 776 mm | 31 kg |
Common specifications
| Specification |
Value |
| Diameter | 95 mm (4") |
| Materials | stainless-steel sleeve, end shields and shaft; R version of the MS 4000 in EN 1.4539 (904L), shaft EN 1.4462 |
| Shaft seal | MS 402: NBR lip seal; MS 4000: ceramic / tungsten carbide, SiC/SiC in the R version |
| Max. operating pressure | MS 402: 15 bar; MS 4000: 60 bar |
| Max. liquid temperature | 40 °C at 0.15 m/s along the motor (60 °C in T60 version) |
| Starts | 100 per hour and 300 per day maximum, at least 1 per year |
| Motor liquid | SML-3 with propylene glycol, frost-proof down to -20 °C |
| Temperature sensor | Tempcon optional on MS 4000 (read by MP 204), Pt1000 with fixing kit |
Data from the Grundfos SP A, SP data booklet (50 Hz). Full data, versions and other voltages on the Grundfos Product Center or on request.