Solar · Storage · Off-grid B2B worldwide export wholesaler

Professional equipment supply for installers, EPC contractors and distributors.

SINES - Grundfos Hydro Multi-E 2 CRE booster set

GRUNDFOS HYDRO MULTI-E CRE



Ready-to-connect booster set: 2, 3 or 4 CRE vertical multistage pumps with MGE motor, stainless-steel manifolds, constant pressure

The Hydro Multi-E is the Grundfos compact booster set for clean-water supply and distribution: two to four CRE 1 to 20 pumps mounted in parallel on a common base frame with their stainless-steel manifolds, isolating valves, non-return valves, dry-running pressure switch, two pressure sensors and diaphragm tank. Each pump has an MGE permanent-magnet motor with built-in frequency converter: the booster set maintains a constant pressure whatever the flow rate, from the water tower to the hotel tap.


CRE 1 and 3

2 or 3 pumps, 0.37 to 1.5 kW
4 to 10 m³/h, up to 105 m

CRE 5 and 10

2 or 3 pumps, 0.55 to 5.5 kW
14 to 36 m³/h, up to 133 m

CRE 15 and 20

2 or 3 pumps, 1.5 to 7.5 kW
41 to 76 m³/h, up to 102 m

Worldwide B2B pump supply and export

CRE pumps are vertical multistage centrifugal pumps in stainless steel, the Grundfos benchmark in pressure boosting. Their MGE permanent-magnet motor, with built-in frequency converter, exceeds the IE4 efficiency level: at partial flow, which is the usual operating condition of a distribution network, the speed drops and consumption falls sharply. The PI controller of the booster set adjusts the speed of the master pump to the pressure setpoint measured at the outlet and cuts in the other pumps in cascade when demand increases, then stops them one by one when it falls. The pumps alternate to spread the operating hours.

Delivered factory-assembled and tested: base frame and suction and discharge manifolds in extruded stainless steel EN 1.4301 (smooth surface, no dead-water zones), an isolating valve on each side of each pump, one non-return valve per pump, pressure gauge, 8 or 12 litre diaphragm tank, breaker cabinet and two redundant outlet pressure sensors: if the master pump or its sensor fails, another pump takes over (multi-master function) and distribution continues. A pressure switch or a level switch (option F) on the suction side stops the booster set in the event of water shortage. All that remains is to connect the pipework and the power supply.

Built-in functions: constant-pressure control, automatic cascade control, pump changeover, limitation of the number of starts per hour, low-flow stop function (the booster set stops on the diaphragm tank and restarts at the start pressure, ΔH adjustable from 5 to 30 %), gradual pipe filling to prevent water hammer on an empty network or in a tall building, three predefined setpoints selectable via digital input, external setpoint influence (flow sensor) and limit-exceeded monitoring (inlet pressure, temperature). Operation via the two buttons on the motor, via the Grundfos GO Remote app or via a BMS through a CIM module (GENIbus, Modbus RTU, PROFIBUS DP, BACnet MS/TP, GSM/GPRS, Grundfos Remote Management).

Applications: drinking-water supply for a village or a district from a tank or a water tower, pressure boosting for apartment buildings, hotels, hospitals, schools, campuses, light industry, pressurised irrigation, complement to an SP + RSI solar borehole to distribute the stored water.

After the solar borehole: a booster set takes over from an SP borehole with RSI inverter that fills the tank or the water tower during the day; it then distributes the stored water at constant pressure, powered by the mains, a generator or a solar system with storage and three-phase inverters (Victron, Studer, SMA Sunny Island X). We size the whole system, from the borehole to the network; see the Grundfos system from A to Z and solar water supply.

Official Grundfos distributor, SINES Export supplies Grundfos booster sets to installers, operators, engineering firms, local authorities and NGOs, for worldwide export: selection of the booster set from your flow and pressure requirements, tender documents, sea or air freight logistics, remote commissioning.

Specification Value
Number of pumps2, 3 or 4
PumpsCRE / CRIE 1, 3, 5, 10, 15 and 20 (stainless-steel vertical multistage)
Motor power per pump0.37 to 7.5 kW
Rated flow rate of the booster set4.4 to 75.9 m³/h
Maximum head14 to 133 m
Maximum operating pressure10 or 16 bar depending on the pump
Liquid / ambient temperature0 to +60 °C / 0 to +50 °C
Inlet pressurecalculated from NPSH (CRE); positive pressure mandatory (CME)
Regulationconstant pressure via PI controller, automatic cascade control, pump changeover, multi-master, low-flow stop, gradual pipe filling, 3 predefined setpoints
Dry-running protectionpressure switch on the suction side or level switch (option F)
Outlet pressure sensors2 (redundant); 1 or one per pump as an option
Diaphragm tank8 or 12 litres, precharge 0.7 × setpoint
Manifolds and base framestainless steel EN 1.4301 (galvanised on CME-A)
Inputs / outputs per pump2 digital inputs, 3 analogue inputs, 2 digital outputs, 2 configurable inputs/outputs
CommunicationGrundfos GO Remote (IR / radio); GENIbus, Modbus RTU, PROFIBUS DP, BACnet MS/TP, GSM/GPRS, GRM via CIM module
Power supplyU1: 3 × 380-415 V, N, PE; U2: 3 × 380-415 V, PE; 50/60 Hz (single-phase U7 / U8 on request)
Enclosure class / insulation classIP54 / class F; starts via the mains supply limited to 4 per hour
Dimensions (L × W × H)780 to 864 × 760 to 1145 × 770 to 1600 mm depending on model
Weight90 to 484.296 kg
Drinking-water approvalACS-approved components (code A)

Official Grundfos documents. Full data booklet, curves and dimensional drawings for each configuration on the Grundfos Product Center or on request from our team.

Need sizing or a schematic diagram? Contact us: we assemble the complete system.

References & article codes


Configurations from the Grundfos catalogue. Rated flow rate and maximum head of the complete booster set; power per pump. Reading a designation: number of pumps, pump type and number of stages, voltage code (U1: 3 × 380-415 V with neutral, written “3 × 400 V + N”; U2: without neutral), then design, starting method, materials, drinking-water approval and options (F: level switch for dry-running protection). Other voltages, numbers of pumps, materials and options on request.

Hydro Multi-E with CRE 1

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
91048813Hydro Multi-E 2 CRE 1-4 U1 A-A-A-F-A4.436100.373 × 400 V + N
91048814Hydro Multi-E 2 CRE 1-4 U2 A-A-A-F-A4.436100.373 × 400 V
91048815Hydro Multi-E 3 CRE 1-4 U1 A-A-A-F-A6.636100.373 × 400 V + N
91048816Hydro Multi-E 3 CRE 1-4 U2 A-A-A-F-A6.636100.373 × 400 V
91048817Hydro Multi-E 2 CRE 1-6 U1 A-A-A-F-A4.454100.553 × 400 V + N
91048818Hydro Multi-E 2 CRE 1-6 U2 A-A-A-F-A4.454100.553 × 400 V
91048819Hydro Multi-E 3 CRE 1-6 U1 A-A-A-F-A6.654100.553 × 400 V + N
91048820Hydro Multi-E 3 CRE 1-6 U2 A-A-A-F-A6.654100.553 × 400 V
91048821Hydro Multi-E 2 CRE 1-9 U1 A-A-A-F-A4.480160.753 × 400 V + N
91048822Hydro Multi-E 2 CRE 1-9 U2 A-A-A-F-A4.481160.753 × 400 V
91048823Hydro Multi-E 3 CRE 1-9 U1 A-A-A-F-A6.680160.753 × 400 V + N
91048824Hydro Multi-E 3 CRE 1-9 U2 A-A-A-F-A6.681160.753 × 400 V

Hydro Multi-E with CRE 3

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
91048825Hydro Multi-E 2 CRE 3-2 U1 A-A-A-F-A719100.373 × 400 V + N
91048826Hydro Multi-E 2 CRE 3-2 U2 A-A-A-F-A719100.373 × 400 V
91048827Hydro Multi-E 3 CRE 3-2 U1 A-A-A-F-A10.519100.373 × 400 V + N
91048828Hydro Multi-E 3 CRE 3-2 U2 A-A-A-F-A10.519100.373 × 400 V
91048829Hydro Multi-E 2 CRE 3-4 U1 A-A-A-F-A737100.553 × 400 V + N
91048830Hydro Multi-E 2 CRE 3-4 U2 A-A-A-F-A738100.553 × 400 V
91048831Hydro Multi-E 3 CRE 3-4 U1 A-A-A-F-A10.537100.553 × 400 V + N
91048832Hydro Multi-E 3 CRE 3-4 U2 A-A-A-F-A10.538100.553 × 400 V
91048833Hydro Multi-E 2 CRE 3-5 U1 A-A-A-F-A747100.753 × 400 V + N
91048834Hydro Multi-E 2 CRE 3-5 U2 A-A-A-F-A748100.753 × 400 V
91048835Hydro Multi-E 3 CRE 3-5 U1 A-A-A-F-A10.547100.753 × 400 V + N
91048836Hydro Multi-E 3 CRE 3-5 U2 A-A-A-F-A10.548100.753 × 400 V
91048837Hydro Multi-E 2 CRE 3-8 U1 A-A-A-F-A774101.13 × 400 V + N
91048838Hydro Multi-E 2 CRE 3-8 U2 A-A-A-F-A776101.13 × 400 V
91048839Hydro Multi-E 3 CRE 3-8 U1 A-A-A-F-A10.574101.13 × 400 V + N
91048840Hydro Multi-E 3 CRE 3-8 U2 A-A-A-F-A10.576101.13 × 400 V
91048841Hydro Multi-E 2 CRE 3-11 U1 A-A-A-F-A7102161.53 × 400 V + N
91048842Hydro Multi-E 2 CRE 3-11 U2 A-A-A-F-A7105161.53 × 400 V
91048843Hydro Multi-E 3 CRE 3-11 U1 A-A-A-F-A10.5102161.53 × 400 V + N
91048844Hydro Multi-E 3 CRE 3-11 U2 A-A-A-F-A10.5105161.53 × 400 V

Hydro Multi-E with CRE 5

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
91048847Hydro Multi-E 2 CRE 5-2 U1 A-A-A-F-A13.820100.553 × 400 V + N
91048848Hydro Multi-E 2 CRE 5-2 U2 A-A-A-F-A13.821100.553 × 400 V
91048849Hydro Multi-E 3 CRE 5-2 U1 A-A-A-F-A20.720100.553 × 400 V + N
91048850Hydro Multi-E 3 CRE 5-2 U2 A-A-A-F-A20.721100.553 × 400 V
91048851Hydro Multi-E 2 CRE 5-4 U1 A-A-A-F-A13.839101.13 × 400 V + N
91048852Hydro Multi-E 2 CRE 5-4 U2 A-A-A-F-A13.841101.13 × 400 V
91048853Hydro Multi-E 3 CRE 5-4 U1 A-A-A-F-A20.739101.13 × 400 V + N
91048854Hydro Multi-E 3 CRE 5-4 U2 A-A-A-F-A20.741101.13 × 400 V
91048855Hydro Multi-E 2 CRE 5-5 U1 A-A-A-F-A13.848101.53 × 400 V + N
91048856Hydro Multi-E 2 CRE 5-5 U2 A-A-A-F-A13.852101.53 × 400 V
91048857Hydro Multi-E 3 CRE 5-5 U1 A-A-A-F-A20.748101.53 × 400 V + N
91048858Hydro Multi-E 3 CRE 5-5 U2 A-A-A-F-A20.752101.53 × 400 V
91048859Hydro Multi-E 2 CRE 5-9 U2 A-A-A-F-A13.893162.23 × 400 V
91048860Hydro Multi-E 3 CRE 5-9 U2 A-A-A-F-A20.793162.23 × 400 V
91048861Hydro Multi-E 2 CRE 5-12 U2 A-A-A-F-A13.81201633 × 400 V
91048862Hydro Multi-E 3 CRE 5-12 U2 A-A-A-F-A20.71201633 × 400 V

Hydro Multi-E with CRE 10

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
91048865Hydro Multi-E 2 CRE 10-1 U1 A-A-A-F-A24.214100.753 × 400 V + N
91048866Hydro Multi-E 2 CRE 10-1 U2 A-A-A-F-A24.214100.753 × 400 V
91048867Hydro Multi-E 3 CRE 10-1 U1 A-A-A-F-A36.314100.753 × 400 V + N
91048868Hydro Multi-E 3 CRE 10-1 U2 A-A-A-F-A36.314100.753 × 400 V
91048869Hydro Multi-E 2 CRE 10-2 U1 A-A-A-F-A24.229101.53 × 400 V + N
91048870Hydro Multi-E 2 CRE 10-2 U2 A-A-A-F-A24.229101.53 × 400 V
91048871Hydro Multi-E 3 CRE 10-2 U1 A-A-A-F-A36.329101.53 × 400 V + N
91048872Hydro Multi-E 3 CRE 10-2 U2 A-A-A-F-A36.329101.53 × 400 V
91048873Hydro Multi-E 2 CRE 10-3 U2 A-A-A-F-A24.244102.23 × 400 V
91048874Hydro Multi-E 3 CRE 10-3 U2 A-A-A-F-A36.344102.23 × 400 V
91048875Hydro Multi-E 2 CRE 10-5 U2 A-A-A-F-A24.2741033 × 400 V
91048876Hydro Multi-E 3 CRE 10-5 U2 A-A-A-F-A36.3741033 × 400 V
91048877Hydro Multi-E 2 CRE 10-6 U2 A-A-A-F-A24.2891643 × 400 V
91048878Hydro Multi-E 3 CRE 10-6 U2 A-A-A-F-A36.3891643 × 400 V
91048879Hydro Multi-E 2 CRE 10-9 U2 A-A-A-F-A24.2133165.53 × 400 V
91048880Hydro Multi-E 3 CRE 10-9 U2 A-A-A-F-A36.3133165.53 × 400 V

Hydro Multi-E with CRE 15

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
91048881Hydro Multi-E 2 CRE 15-1 U1 A-A-A-F-A4119101.53 × 400 V + N
91048882Hydro Multi-E 2 CRE 15-1 U2 A-A-A-F-A4120101.53 × 400 V
91048883Hydro Multi-E 3 CRE 15-1 U1 A-A-A-F-A61.519101.53 × 400 V + N
91048884Hydro Multi-E 3 CRE 15-1 U2 A-A-A-F-A61.520101.53 × 400 V
91048885Hydro Multi-E 2 CRE 15-2 U2 A-A-A-F-A41411033 × 400 V
91048886Hydro Multi-E 3 CRE 15-2 U2 A-A-A-F-A61.5411033 × 400 V
91048887Hydro Multi-E 2 CRE 15-3 U2 A-A-A-F-A41621043 × 400 V
91048888Hydro Multi-E 3 CRE 15-3 U2 A-A-A-F-A61.5621043 × 400 V
91048889Hydro Multi-E 2 CRE 15-4 U2 A-A-A-F-A4182165.53 × 400 V
91048890Hydro Multi-E 3 CRE 15-4 U2 A-A-A-F-A61.582165.53 × 400 V
91048891Hydro Multi-E 2 CRE 15-5 U2 A-A-A-F-A41102167.53 × 400 V
91048892Hydro Multi-E 3 CRE 15-5 U2 A-A-A-F-A61.5102167.53 × 400 V

Hydro Multi-E with CRE 20

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
91048893Hydro Multi-E 2 CRE 20-1 U2 A-A-A-F-A50.620102.23 × 400 V
91048894Hydro Multi-E 3 CRE 20-1 U2 A-A-A-F-A75.920102.23 × 400 V
91048895Hydro Multi-E 2 CRE 20-2 U2 A-A-A-F-A50.6421043 × 400 V
91048896Hydro Multi-E 3 CRE 20-2 U2 A-A-A-F-A75.9421043 × 400 V
91048897Hydro Multi-E 2 CRE 20-3 U2 A-A-A-F-A50.663105.53 × 400 V
91048898Hydro Multi-E 3 CRE 20-3 U2 A-A-A-F-A75.963105.53 × 400 V
91048899Hydro Multi-E 2 CRE 20-4 U2 A-A-A-F-A50.685167.53 × 400 V
91048900Hydro Multi-E 3 CRE 20-4 U2 A-A-A-F-A75.985167.53 × 400 V

Hydro Multi-E with CRIE 10

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
99133119Hydro Multi-E 3 CRIE 10-5 U2 A-A-A-A-A36.3741033 × 400 V

Size your solar pumping system in two minutes

LE LAB, our free online tool, sizes it from your water need, the depth and your location: recommended pump, controller and PV power. No account required.

Launch LE LAB Or request a free study
Project support · Worldwide delivery

Get the support your project needs

From product selection to export logistics, our team helps installers, EPCs and distributors turn a requirement into a clear professional quotation.

B2B supply Sea or air freight Worldwide export
From requirement to delivery
  1. 01Share your products and quantities
  2. 02Receive a clear B2B quotation
  3. 03We coordinate worldwide delivery
Start your request