Solar · Storage · Off-grid B2B worldwide export wholesaler

Professional equipment supply for installers, EPC contractors and distributors.

SINES - Grundfos Hydro MPC-E 3 CRE booster set with CU 352 control cabinet

GRUNDFOS HYDRO MPC



The Grundfos benchmark booster set: 2 to 6 CR or CRE pumps, CU 352 control cabinet with touch screen, up to 725 m³/h

The Hydro MPC is the Grundfos booster set for water supply networks, towns and districts, hospitals, hotels and industry: two to six CR or CRE vertical multistage pumps on a common base frame, stainless-steel manifolds, and a CU 352 control cabinet with touch screen that controls the pressure and manages cascade operation, standby pumps, alarms and communication. In the MPC-E version, each CRE pump has its own built-in frequency converter; in the MPC-F version, the CR pumps are controlled by an external frequency converter in the cabinet.


MPC-E CRE 10 to 20

2 or 3 pumps, 1.5 to 11 kW
22 to 76 m³/h, up to 149 m

MPC-E CRE 32 to 64

2 to 4 pumps, 2.2 to 22 kW
72 to 308 m³/h, up to 102 m

MPC-F 3 CR 15

3 pumps, 5.5 and 7.5 kW
51 m³/h, 98 to 127 m

Worldwide B2B pump supply and export

CR and CRE pumps are stainless-steel vertical multistage pumps (CRI and CRIE all stainless steel up to size 20, cast iron and stainless steel above), with an HQQE silicon carbide cartridge shaft seal that can be replaced without dismantling the pump. The MGE motors of the CRE pumps incorporate the frequency converter; above 30 kW or on MPC-F sets, the frequency converter is installed in the cabinet. Each pump can be removed without touching the pipework thanks to its isolating valves and its non-return valve: maintenance of a six-pump booster set is carried out pump by pump, without cutting off the water. Stainless-steel EN 1.4401 manifolds with R 2 to R 2½ union connections or DN 80 to DN 250 flanges, operating pressure 16 bar as standard (higher on request), liquid from 0 to 70 °C.

The CU 352 cabinet controls the whole set from its colour touch screen: constant-pressure control with redundant primary sensor, automatic cascade control, alternative setpoints, limitation of starts per hour, standby pumps, forced pump changeover, periodic pump test run, dry-running protection by pressure switch, level switch or analogue sensor, low-flow stop function, password. The IO 351 modules add inputs and outputs; the G100 gateway and the CIM modules open the booster set to remote monitoring (GENIbus, Modbus, PROFIBUS, GSM). Cabinet options: main switch with neutral disconnection, manual-off-auto selector switch, indicator lights, beacon and audible alarm, voltmeter and ammeter, phase asymmetry monitoring, surge arrester.

The booster set is delivered assembled and tested, on a stainless-steel or galvanised base frame depending on the version, for indoor installation on a concrete foundation with a mass equal to 1.5 times its own, with 1 m of clearance in front and on the sides. The MPC-E 2 and 3 CRE 10 to 64 and MPC-F 3 CR 15 versions in the Grundfos catalogue cover from 22 to 308 m³/h rated flow and up to 149 m; configurations with 4, 5 or 6 pumps, CR 90 pumps, pressures above 16 bar and custom-built booster sets are produced by Grundfos on request from your flow and pressure requirements.

Applications: water supply and distribution for towns and districts from a storage tank, filling and pressure boosting of water towers, large hospitals and hotels, campuses and barracks, industrial estates, pressurised collective irrigation, NGO and local-authority projects worldwide.

After the solar borehole: a booster set takes over from an SP borehole with RSI inverter that fills the tank or the water tower during the day; it then distributes the stored water at constant pressure, powered by the mains, a generator or a solar system with storage and three-phase inverters (Victron, Studer, SMA Sunny Island X). We size the whole system, from the borehole to the network; see the Grundfos system from A to Z and solar water supply.

Official Grundfos distributor, SINES Export supplies Grundfos booster sets to installers, operators, engineering firms, local authorities and NGOs, for worldwide export: selection of the booster set from your flow and pressure requirements, tender documents, sea or air freight logistics, remote commissioning.

Specification Value
VariantsMPC-E: CRE pumps with built-in frequency converter, 0.37 to 22 kW; MPC-F: CR pumps and external frequency converters in the cabinet, 1.1 to 30 kW; MPC-S (fixed speed), -ED, -ES, -EF, -EDF on request
Number of pumps2 to 6 (catalogue: 2 to 4)
PumpsCR / CRE 10, 15, 20, 32, 45, 64 (CRI 3 and 5, CR 90 on request)
Motor power per pump (catalogue)1.5 to 22 kW
Rated flow rate of the booster set (catalogue)22.46 to 308 m³/h
Maximum head19.6 to 149 m (full range up to 145 m, 725 m³/h)
Maximum operating pressure16 bar as standard, higher on request
Liquid / ambient temperature0 to +70 °C / 0 to +40 °C, humidity 95 %
Control cabinetCU 352 with colour touch screen, IO 351A / IO 351B modules, external frequency converters (MPC-F), ventilation
Regulationconstant pressure with redundant primary sensor, automatic cascade control, alternative setpoints, standby pumps, forced pump changeover, pump test run, low-flow stop, limitation of starts per hour
Dry-running protectionpressure switch, level switch or analogue sensor on the suction side
Shaft sealHQQE SiC/SiC/EPDM cartridge seal, replaceable without dismantling the pump
MaterialsCRI(E) 3 to 20: stainless steel EN 1.4301; CR(E) 32 to 90: cast iron and stainless steel; manifolds in stainless steel EN 1.4401 (galvanised on request)
Connectionunion connection R 2 to R 2½ or DIN flanges DN 80 to DN 250
CommunicationGENIbus, G100 gateway, CIM modules (Modbus, PROFIBUS, GSM), Grundfos Remote Management
Power supply3 × 380-415 V, 50 Hz; IP55 motors (IP65 on request), PTC sensors from 3 kW
Weight (catalogue)190.759 to 1151.22 kg
Installationindoors, concrete foundation of 1.5 × the weight of the booster set, 1 m of clearance in front and on the sides, vibration dampers and expansion joints recommended

Official Grundfos documents. Full data booklet, curves and dimensional drawings for each configuration on the Grundfos Product Center or on request from our team.

Need sizing or a schematic diagram? Contact us: we assemble the complete system.

References & article codes


Configurations from the Grundfos catalogue. Rated flow rate and maximum head of the complete booster set; power per pump. Reading a designation: number of pumps, pump type and number of stages, voltage code (U1: 3 × 380-415 V with neutral, written “3 × 400 V + N”; U2: without neutral), then design, starting method, materials, drinking-water approval and options (F: level switch for dry-running protection). Other voltages, numbers of pumps, materials and options on request.

MPC-E with CRE 10

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
93460921Hydro MPC-E 2 CRE10-2 V2 GA-A-A-A22.4629.2161.53 × 400 V
93460922Hydro MPC-E 3 CRE10-2 V2 GA-A-A-A33.6929.2161.53 × 400 V
93460925Hydro MPC-E 3 CRE10-3 V2 GA-A-A-A35.1644162.23 × 400 V
93460928Hydro MPC-E 3 CRE10-5 V2 GA-A-A-A36.4273.31633 × 400 V
93460931Hydro MPC-E 3 CRE10-6 V2 GA-A-A-A36.5488.21643 × 400 V
93460934Hydro MPC-E 3 CRE10-9 V2 GA-A-A-A36.45131.8165.53 × 400 V

MPC-E with CRE 15

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
93460936Hydro MPC-E 2 CRE15-1 V2 GA-A-A-A38.7219.6161.53 × 400 V
93460937Hydro MPC-E 3 CRE15-1 V2 GA-A-A-A58.0819.6161.53 × 400 V
93460940Hydro MPC-E 3 CRE15-2 V2 GA-A-A-A62.4339.91633 × 400 V
93460942Hydro MPC-E 2 CRE15-3 V2 GA-A-A-A42.160.91643 × 400 V
93460943Hydro MPC-E 3 CRE15-3 V2 GA-A-A-A63.1560.91643 × 400 V
93460945Hydro MPC-E 2 CRE15-4 V2 GA-A-A-A40.981.1165.53 × 400 V
93460946Hydro MPC-E 3 CRE15-4 V2 GA-A-A-A61.3581.1165.53 × 400 V
93460948Hydro MPC-E 2 CRE15-5 V2 GD-A-A-A42.82101.2167.53 × 400 V
93460949Hydro MPC-E 3 CRE15-5 V2 GD-A-A-A64.23101.2167.53 × 400 V
93460951Hydro MPC-E 2 CRE15-7 V2 GD-A-A-AU41.02140.8167.53 × 400 V
93460952Hydro MPC-E 3 CRE15-7 V2 GD-A-A-AU61.53140.8167.53 × 400 V

MPC-E with CRE 20

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
93460954Hydro MPC-E 2 CRE20-1 V2 GA-A-A-A4020.9162.23 × 400 V
93460955Hydro MPC-E 3 CRE20-1 V2 GA-A-A-A6020.9162.23 × 400 V
93460957Hydro MPC-E 2 CRE20-2 V2 GA-A-A-A45.7241.71643 × 400 V
93460958Hydro MPC-E 3 CRE20-2 V2 GA-A-A-A68.5841.71643 × 400 V
93460970Hydro MPC-E 2 CRE20-3 V2 GA-A-A-A47.7662.7165.53 × 400 V
93460971Hydro MPC-E 3 CRE20-3 V2 GA-A-A-A71.6462.7165.53 × 400 V
93460973Hydro MPC-E 2 CRE20-4 V2 GD-A-A-A48.583.7167.53 × 400 V
93460974Hydro MPC-E 3 CRE20-4 V2 GD-A-A-A72.7583.7167.53 × 400 V
93460976Hydro MPC-E 2 CRE20-7 V2 GD-A-A-APU50.614916113 × 400 V
93460977Hydro MPC-E 3 CRE20-7 V2 GD-A-A-APU75.914916113 × 400 V

MPC-E with CRE 32

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
93460982Hydro MPC-E 2 CRE32-1 V2 GD-A-A-A72291633 × 400 V
93460983Hydro MPC-E 3 CRE32-1 V2 GD-A-A-A108291633 × 400 V
93460979Hydro MPC-E 2 CRE32-1-1 V2 GD-A-A-A7221.5162.23 × 400 V
93460980Hydro MPC-E 3 CRE32-1-1 V2 GD-A-A-A10821.5162.23 × 400 V
93460985Hydro MPC-E 2 CRE32-2 V2 GD-A-A-A7257.2167.53 × 400 V
93460989Hydro MPC-E 3 CRE32-4-2 V2 GD-A-A-A108101.916113 × 400 V

MPC-E with CRE 45

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
93461000Hydro MPC-E 2 CRE45-1 V2 GD-A-A-A10838.6167.53 × 400 V
93461001Hydro MPC-E 3 CRE45-1 V2 GD-A-A-A16238.6167.53 × 400 V
93460997Hydro MPC-E 2 CRE45-1-1 V2 GD-A-A-A10831165.53 × 400 V
93460998Hydro MPC-E 3 CRE45-1-1 V2 GD-A-A-A16231165.53 × 400 V
93461006Hydro MPC-E 2 CRE45-2 V2 GD-A-A-A1087516153 × 400 V
93461003Hydro MPC-E 2 CRE45-2-2 V2 GD-A-A-A10859.816113 × 400 V
93461004Hydro MPC-E 3 CRE45-2-2 V2 GD-A-A-A16259.816113 × 400 V

MPC-E with CRE 64

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
93461018Hydro MPC-E 2 CRE64-1 V2 GD-A-A-A15446.916113 × 400 V
93461019Hydro MPC-E 3 CRE64-1 V2 GD-A-A-A23146.916113 × 400 V
93461015Hydro MPC-E 2 CRE64-1-1 V2 GD-A-A-A15432167.53 × 400 V
93461016Hydro MPC-E 3 CRE64-1-1 V2 GD-A-A-A23132167.53 × 400 V
93461029Hydro MPC-E 4 CRE64-3-2 V2 GD-A-A-A308101.116223 × 400 V

MPC-F with CR 15

Article code Designation Rated flow rate
(m³/h)
Max. head
(m)
Max. pressure
(bar)
Motor / pump
(kW)
Power supply
91049307Hydro MPC-F 3 CR15-7 U4 D-B-AA-A5198.5165.53 × 400 V
91049308Hydro MPC-F 3 CR15-9 U4 D-B-AA-A51127167.53 × 400 V

Size your solar pumping system in two minutes

LE LAB, our free online tool, sizes it from your water need, the depth and your location: recommended pump, controller and PV power. No account required.

Launch LE LAB Or request a free study
Project support · Worldwide delivery

Get the support your project needs

From product selection to export logistics, our team helps installers, EPCs and distributors turn a requirement into a clear professional quotation.

B2B supply Sea or air freight Worldwide export
From requirement to delivery
  1. 01Share your products and quantities
  2. 02Receive a clear B2B quotation
  3. 03We coordinate worldwide delivery
Start your request