Solar · Storage · Off-grid Wholesale solar, storage and off-grid equipment

We supply installers, EPC contractors and distributors worldwide.

SINES - Grundfos CUE 3 × 380-500 V IP55 / IP54


GRUNDFOS CUE 3 × 400 V IP55 / IP54



Grundfos frequency converter 3 × 380-500 V in IP55 enclosure from 0.55 to 90 kW and IP54 from 110 to 560 kW, with or without STO

The IP55 / IP54 version of the CUE is mounted on the wall of a plant room with no additional cabinet. Outdoors, Grundfos requires protection against water and sun.


0.55 to 560 kW

motor power
P2

3 × 400 V

range 380-500 V
50 / 60 Hz

IP55 / IP54

sealed enclosure
with or without STO

Worldwide B2B pump supply and export

The CUE 3 × 380-500 V in IP55 (0.55 to 90 kW) and IP54 (110 to 560 kW) is mounted directly in a plant room or a pumping station. It is available in a standard version and in an STO version, with a Safe Torque Off safety stop controlled by a single wire (Grundfos brochure).

The size is selected on the motor current and not on its power alone, as Grundfos points out for SPE pumps: in its selection table, a 7.5 kW SPE motor (16.6 A) requires a 11 kW CUE. The table gives the rated current of each size and the filters matched to it by Grundfos.

The IP55 / IP54 enclosure must not be installed outdoors without additional protection against water and sun (Grundfos manual): provide a ventilated shelter at open-air pumping stations.

Applications: pumping stations and boreholes equipped with SP or SPE pumps, CR and CRN pressure boosting, irrigation, plant rooms without a cabinet.

Official Grundfos distributor, SINES Export supplies CUE frequency converters, their filters and their accessories to installers, integrators, engineering firms and operators, for worldwide export. Send us the motor nameplate and the cable length: we select the right CUE size and filter. See also the SP submersible pumps, the variable-speed SPE pumps and the CR and CRN pumps.

Sizes in the Grundfos 2026 catalogue

Power P2 Rated current In (A) Matching dU/dt filter Matching sine-wave filter Versions
0.55 kW1.8 / 1.6–96754941IP55 · IP55 STO DC
0.75 kW2.4 / 2.1–96754941IP55 · IP55 STO DC
1.1 kW3 / 2.7–96754972IP55 · IP55 STO DC
1.5 kW4.1 / 3.4–96754972IP55 · IP55 STO DC
2.2 kW5.6 / 4.8–96754973IP55 · IP55 STO DC
3 kW7.2 / 6.3–96754973IP55 · IP55 STO DC
4 kW10 / 8.2–96754974IP55 · IP55 STO DC
5.5 kW13 / 11–96754976IP55 · IP55 STO DC
7.5 kW16 / 14.5–96754976IP55 · IP55 STO DC
11 kW24 / 219766979996754977IP55 · IP55 STO DC
15 kW32 / 279766979996754978IP55 · IP55 STO DC
18.5 kW37.5 / 349766979996754978IP55 · IP55 STO DC
22 kW44 / 409766979996755019IP55 · IP55 STO DC
30 kW61 / 529766986996755021IP55 · IP55 STO DC
37 kW73 / 659766986996755032IP55 · IP55 STO DC
45 kW90 / 809766986997774436IP55 · IP55 STO DC
55 kW106 / 1059766989697774436IP55 · IP55 STO DC
75 kW147 / 1309766990297775142IP55 · IP55 STO DC
90 kW177 / 1609766990297775142IP55 · IP55 STO DC
110 kW212 / 1909766990597775146IP54 · IP54 STO DC
132 kW260 / 2409766990597775146IP54 · IP54 STO DC
160 kW315 / 3029766990597775148IP54 · IP54 STO DC
200 kW395 / 3619766990697775148IP54 · IP54 STO DC
250 kW480 / 4439766990697775149IP54 · IP54 STO DC
355 kW658 / 5909330317293303174IP54 DC · IP54 STO DC
400 kW745 / 6789330317393303175IP54 DC · IP54 STO DC
450 kW800 / 730933031732 × 97775149IP54 DC · IP54 STO DC
500 kW880 / 780933031732 × 97775149IP54 DC · IP54 STO DC
560 kW990 / 890933031732 × 93303174IP54 DC · IP54 STO DC

Rated current: two values depending on the supply voltage range, the first at 3 × 380-440 V. Filters matched by Grundfos to each size; the choice between dU/dt and sine-wave depends on the pump and the cable length.

When is an output filter required?

Use case (CUE manual) CUE power dU/dt filter Sine-wave filter
SP, BM, BMB pumps with motors of 380 V and aboveall–0 to 300 m
MG71 and MG80 motors up to and including 1.5 kWCUE above 1.5 kW–0 to 300 m
Reduction of dU/dt and noise, low reductionall0 to 150 m–
Reduction of dU/dt, voltage peaks and noise, high reductionall–0 to 300 m
Motors of 500 V and aboveall–0 to 300 m

Common specifications

Specification Value
Functionexternal frequency converter designed for Grundfos pumps, with a start-up guide for each pump family (CR, CRI, CRN, CRT, SP, SP-G, SP-NE…)
Control modesopen loop, constant pressure, constant or proportional differential pressure, constant flow rate, constant temperature, constant level, other constant value
Inputs and outputs1 RS-485 GENIbus port, 1 analogue input 0-10 V / 0-4-20 mA for the external setpoint, 1 analogue input 0-4-20 mA for the sensor, 1 analogue output 0-20 mA, 4 digital inputs (start / stop and 3 programmable), 2 programmable relays
CommunicationGENIbus as standard; other protocols via a CIU communication unit
Motor cablescreened to comply with EN 61800-3; 150 m maximum screened, 300 m unscreened; beyond that, please consult us
InstallationIP20 / IP21 in a cabinet only; IP54 / IP55 never outdoors without protection against water and sun
Altitudeabove 2 000 m, the CUE derates its output: a larger size may be required

Sources: Grundfos CUE manual, Grundfos SPE data booklet and Grundfos 2026 catalogue.

Official Grundfos documents.

The online manual covers CUE units from 0.55 to 90 kW; for sizes of 110 kW and above, we supply the corresponding Grundfos manual with the quotation.

To select the size and the filter, contact us with the motor nameplate, the site voltage and the motor cable length.

References & article codes


Grundfos 2026 catalogue codes. In: two values depending on the voltage range, the first at 3 × 380-440 V. Matching filters according to the Grundfos 2026 catalogue.

Standard versions

Article code Designation Power P2 In (A) dU/dt filter Sine-wave filter
99616756CUE 3 × 380-500 V IP55 0.55 kW0.55 kW1.8 / 1.6–96754941
99616757CUE 3 × 380-500 V IP55 0.75 kW0.75 kW2.4 / 2.1–96754941
99616758CUE 3 × 380-500 V IP55 1.1 kW1.1 kW3 / 2.7–96754972
99616759CUE 3 × 380-500 V IP55 1.5 kW1.5 kW4.1 / 3.4–96754972
99616760CUE 3 × 380-500 V IP55 2.2 kW2.2 kW5.6 / 4.8–96754973
99616761CUE 3 × 380-500 V IP55 3 kW3 kW7.2 / 6.3–96754973
99616762CUE 3 × 380-500 V IP55 4 kW4 kW10 / 8.2–96754974
99616763CUE 3 × 380-500 V IP55 5.5 kW5.5 kW13 / 11–96754976
99616764CUE 3 × 380-500 V IP55 7.5 kW7.5 kW16 / 14.5–96754976
99616765CUE 3 × 380-500 V IP55 11 kW11 kW24 / 219766979996754977
99616766CUE 3 × 380-500 V IP55 15 kW15 kW32 / 279766979996754978
99616767CUE 3 × 380-500 V IP55 18.5 kW18.5 kW37.5 / 349766979996754978
99616769CUE 3 × 380-500 V IP55 22 kW22 kW44 / 409766979996755019
99616770CUE 3 × 380-500 V IP55 30 kW30 kW61 / 529766986996755021
99616771CUE 3 × 380-500 V IP55 37 kW37 kW73 / 659766986996755032
99616772CUE 3 × 380-500 V IP55 45 kW45 kW90 / 809766986997774436
99616773CUE 3 × 380-500 V IP55 55 kW55 kW106 / 1059766989697774436
99616774CUE 3 × 380-500 V IP55 75 kW75 kW147 / 1309766990297775142
99616775CUE 3 × 380-500 V IP55 90 kW90 kW177 / 1609766990297775142
99616776CUE 3 × 380-500 V IP54 110 kW110 kW212 / 1909766990597775146
99616777CUE 3 × 380-500 V IP54 132 kW132 kW260 / 2409766990597775146
99616778CUE 3 × 380-500 V IP54 160 kW160 kW315 / 3029766990597775148
99616779CUE 3 × 380-500 V IP54 200 kW200 kW395 / 3619766990697775148
99616780CUE 3 × 380-500 V IP54 250 kW250 kW480 / 4439766990697775149
93021211CUE 3 × 380-500 V IP54 355 kW DC355 kW658 / 5909330317293303174
93021212CUE 3 × 380-500 V IP54 400 kW DC400 kW745 / 6789330317393303175
93021213CUE 3 × 380-500 V IP54 450 kW DC450 kW800 / 730933031732 × 97775149
93021214CUE 3 × 380-500 V IP54 500 kW DC500 kW880 / 780933031732 × 97775149
93021215CUE 3 × 380-500 V IP54 560 kW DC560 kW990 / 890933031732 × 93303174

STO versions

Article code Designation Power P2 In (A) dU/dt filter Sine-wave filter
99616781CUE 3 × 380-500 V IP55 0.55 kW STO DC0.55 kW1.8 / 1.6–96754941
99616782CUE 3 × 380-500 V IP55 0.75 kW STO DC0.75 kW2.4 / 2.1–96754941
99616783CUE 3 × 380-500 V IP55 1.1 kW STO DC1.1 kW3 / 2.7–96754972
99616784CUE 3 × 380-500 V IP55 1.5 kW STO DC1.5 kW4.1 / 3.4–96754972
99616785CUE 3 × 380-500 V IP55 2.2 kW STO DC2.2 kW5.6 / 4.8–96754973
99616786CUE 3 × 380-500 V IP55 3 kW STO DC3 kW7.2 / 6.3–96754973
99616787CUE 3 × 380-500 V IP55 4 kW STO DC4 kW10 / 8.2–96754974
99616788CUE 3 × 380-500 V IP55 5.5 kW STO DC5.5 kW13 / 11–96754976
99616789CUE 3 × 380-500 V IP55 7.5 kW STO DC7.5 kW16 / 14.5–96754976
99616790CUE 3 × 380-500 V IP55 11 kW STO DC11 kW24 / 219766979996754977
99616791CUE 3 × 380-500 V IP55 15 kW STO DC15 kW32 / 279766979996754978
99616792CUE 3 × 380-500 V IP55 18.5 kW STO DC18.5 kW37.5 / 349766979996754978
99616793CUE 3 × 380-500 V IP55 22 kW STO DC22 kW44 / 409766979996755019
99616794CUE 3 × 380-500 V IP55 30 kW STO DC30 kW61 / 529766986996755021
99616795CUE 3 × 380-500 V IP55 37 kW STO DC37 kW73 / 659766986996755032
99616796CUE 3 × 380-500 V IP55 45 kW STO DC45 kW90 / 809766986997774436
99616797CUE 3 × 380-500 V IP55 55 kW STO DC55 kW106 / 1059766989697774436
99616798CUE 3 × 380-500 V IP55 75 kW STO DC75 kW147 / 1309766990297775142
99616799CUE 3 × 380-500 V IP55 90 kW STO DC90 kW177 / 1609766990297775142
99616800CUE 3 × 380-500 V IP54 110 kW STO DC110 kW212 / 1909766990597775146
99616801CUE 3 × 380-500 V IP54 132 kW STO DC132 kW260 / 2409766990597775146
99616802CUE 3 × 380-500 V IP54 160 kW STO DC160 kW315 / 3029766990597775148
99616803CUE 3 × 380-500 V IP54 200 kW STO DC200 kW395 / 3619766990697775148
99616804CUE 3 × 380-500 V IP54 250 kW STO DC250 kW480 / 4439766990697775149
93021216CUE 3 × 380-500 V IP54 355 kW STO DC355 kW658 / 5909330317293303174
93021217CUE 3 × 380-500 V IP54 400 kW STO DC400 kW745 / 6789330317393303175
93021218CUE 3 × 380-500 V IP54 450 kW STO DC450 kW800 / 730933031732 × 97775149
93021219CUE 3 × 380-500 V IP54 500 kW STO DC500 kW880 / 780933031732 × 97775149
93021220CUE 3 × 380-500 V IP54 560 kW STO DC560 kW990 / 890933031732 × 93303174

Size your solar pumping system

Enter your water demand, pumping depth and location. LE LAB recommends a pump, a controller and the PV power needed. The tool is free to use without an account.

Launch LE LAB Or request a free study
Project support · Worldwide delivery

Request a trade quote

Send us your product list or tell us what you need. We can help with equipment selection and quote for delivery.

B2B supply Sea or air freight Worldwide export
How to order
  1. 01Send your product list and quantities
  2. 02Get a quote with prices and lead times
  3. 03Confirm your order and we’ll arrange shipping
Request a quote