A drop-in lithium battery with built-in BMS
The Victron Lithium SuperPack NG is a LiFePO₄ battery designed as a drop-in replacement for standard lead-acid batteries in RVs and recreational vehicles, in retrofits as well as in original installations. Its form factor and terminal layout make installation easy in vehicles such as large trucks, SUVs and RVs. The battery management system and the battery monitor are built in (cell balancing, protection and monitoring functions), so no external battery management system is required. The range covers 12.8 V (100 and 200 Ah), 25.6 V (100 and 200 Ah) and 51.2 V (100 Ah) models, with a nominal energy of 1280 Wh to 5120 Wh at 25 °C.
Bluetooth monitoring, EFS output and on/off button
Bluetooth Smart allows wireless configuration, monitoring and firmware updates with the VictronConnect app; the Instant Readout function shows the state of charge, battery temperature, warnings and alarms directly in the device list, without connecting. The wired communication is an External Feedback Signal (EFS): a battery voltage signal limited to 250 mA that acts as an External Disconnection Signal (EDS) for redundant system protection, or can be configured as an External Charging Signal (ECS), based on the low SoC pre-alarm threshold, to start a charger. Two LEDs indicate Bluetooth connectivity, warning and alarm conditions or firmware update status, and an on/off push button disables both charging and discharging for safe operation and extended storage. A configurable discharge floor keeps a minimum state of charge in reserve: when it is reached, VictronConnect shows a Low SoC alarm and the Allowed to Discharge (ATD) indicator turns off until the state of charge rises above the threshold.
Self-heating for charging in cold conditions
The self-heating function keeps the cells above the minimum safe charging temperature. In Charger mode (default), the heater is powered by the connected charger and activates automatically when the cell temperature drops below 0 °C before charging. In Auto mode, the battery powers the heater itself so that charging can start immediately, within the limit of its internal energy: below the Low SoC threshold the heater is disconnected and charging remains unavailable. The maximum self-heating power is 65 W (12.8 V/100Ah), 130 W (12.8 V/200Ah and 25.6 V/100Ah) and 260 W (25.6 V/200Ah and 51.2 V/100Ah). The operating temperature range is -30 °C to +60 °C for charge and discharge; below 0 °C, charging is suspended while the cells are warmed and resumes automatically once a safe charging temperature is reached.
Main specifications
Cycle life at 25 °C (capacity ≥ 80 % of nominal): 2500 cycles at 80 % DoD, 3000 cycles at 70 % DoD and 5000 cycles at 50 % DoD. For the 12.8 V, 25.6 V and 51.2 V models respectively, the recommended charging voltage is 14 V, 28 V and 56 V, the float voltage 13.5 V, 27 V and 54 V, and the charging voltage range 13.5 – 14.2 V, 27 – 28.4 V and 54 – 56.8 V. The 100 Ah models accept a recommended discharge current of 50 A, a maximum continuous discharge current of 200 A, a recommended charging current of 30 A and a maximum continuous charging current of 100 A; the 200 Ah models 100 A, 400 A, 60 A and 200 A. The datasheet specifies that, at 25 °C ambient and 100 % SoC, 2C can be sustained for approximately 10 minutes, depending on temperature and voltage protection limits. Protections: short circuit above 800 A (hardware), overvoltage, undervoltage, overtemperature, undertemperature and overcurrent (software). Batteries can be connected in parallel without limit on energy expansion, with power expansion limited to the maximum current of the system; series connection is not supported.
Protection class IP65, power connection by M8 female threaded insert, mounting upright or on its long side on a flat horizontal support. Dimensions (L x W x H): 273 x 173 x 173 mm for the 12.8 V/100Ah, compatible with BCI Group 49 dimensions; 466 x 198 x 173 mm for the 12.8 V/200Ah and 25.6 V/100Ah; 871 x 198 x 173 mm for the 25.6 V/200Ah and 51.2 V/100Ah; terminal screws add 15 mm in height. Safety standards listed for the cells: IEC 62619, UL 1973 and UL 9540A; transport: UN38.3.