Hybrid inverter/charger with built-in solar charger
The Multi RS Solar 48/6000/100 combines in one enclosure a 48 V inverter/charger with a 230 VAC output and a solar charger with two independent MPPT trackers. Each tracker accepts a PV array open-circuit voltage of up to 450 V and converts up to 3 kW, for 6 kW in total; the maximum PV voltage should also not exceed 8 times the battery float voltage. Its high-frequency design keeps the unit light (12.3 kg), efficient and quiet, with low standby power.
Five operating modes
• Hybrid mode: excess solar energy is stored in the battery for use at night or during periods of high demand, and the battery supplies additional power when demand exceeds the grid capacity.
• Backup mode: the unit switches to backup operation during a grid outage.
• Off-grid mode: operation without any grid connection.
• Generator mode: the generator is controlled to minimise its run-hours, and the battery supplies additional power when demand exceeds the generator capacity.
• PV inverter mode: operation as a PV inverter without a battery.
PowerControl and PowerAssist
A maximum grid or generator current can be set: the Multi RS Solar takes the other AC loads into account and uses only the spare current for battery charging, so that the generator or the grid is not overloaded (PowerControl). With PowerAssist, peaks that exceed the grid or generator capacity are covered by the battery, which is recharged when the load decreases. A second AC output (AC-out-2), connected directly to the AC input, is intended for non-critical loads and is taken into account by PowerControl and PowerAssist.
Extendable PV capacity, AC-coupled or DC-coupled
The integrated 6 kWp PV capacity can be extended by adding solar chargers to the system, or by installing PV inverters, whose output power is then automatically controlled by the built-in frequency shift power control.
Three-phase systems
Three-phase systems are built with one Multi RS Solar per phase. Parallel operation of several units is not supported.
Display, Bluetooth and system monitoring
The built-in display shows battery, inverter and solar parameters, which can also be read over Bluetooth with the VictronConnect app for monitoring, settings, historical trends and firmware updates. The VE.Can port connects the unit to a GX device such as the Cerbo GX for system monitoring, energy meter connection, data logging, remote firmware updates and ESS functions such as zero feed-in and backup of critical loads during outages. A VE.Direct port is provided for a GlobalLink 520. The programmable relay, temperature sensor and voltage sensor connections complete the I/O.
Main technical data (official datasheet)
• Battery: 48 V, DC input voltage range 38 – 62 V
• AC output: 230 VAC ± 2 %, 50 Hz ± 0,1 %, maximum continuous inverter current 25 Aac
• Continuous output power at 25 °C: increases linearly from 4600 W at 46 VDC to 5200 W at 52 VDC; 4500 W at 40 °C; 3000 W at 65 °C
• Peak power: 9 kW for 3 seconds, 7 kW for 4 minutes
• Efficiency: 96,5 % at 1 kW load, 94 % at 5 kW load; zero load power consumption 20 W
• Solar: maximum open circuit PV array voltage 450 V, start-up voltage 120 V, MPPT operating range 65 – 450 V, maximum PV conversion power 6 kW total – 3 kW per tracker
• Charger: AC input 187-265 VAC, maximum charge current from AC 88 A at 57.6 VDC, total maximum charge current (AC + PV) 100 A DC
• Transfer switch and maximum AC input current: 50 A
• Enclosure: steel, blue RAL 5012, IP21; operating temperature -40 to +65 °C (fan assisted cooling)
• Weight 12.3 kg; dimensions (h x w x d) 462 x 425 x 127 mm